Manufacturer | Fireboy-Xintex | |
MFG NO | OMHD-04-DB-R | |
SKU | 6209106 | |
UPC | 619749321088 |
Rate-of-Rise Heat Detector with BaseThe Fireboy-Xintex Heat Detector uses a single thermistor to sense the air temperature around the detector. This heat detector was designed to detect how fast the temperature is increasing.Features:163°F Rate-of-Rise Heat DetectorHousing: White flame-retardant polycarbonateTerminals: Nickel-plated stainless steelIdeal in environments that are dirty or smokyUnaffected by wind or atmospheric pressureRemote test featureSpecifications:Detection Principle: Measurement of heat using a thermistorSampling Frequency: Once every four secondsSupply Voltage: 8.5 V dc to 33 V dcSupply Wiring: Two wire supply, polarity sensitivePower-up Time: Minimum: ‘detector active’ voltage: 6 VHolding Voltage: 5 V - 33 VMinimum Holding Current: 8 mA Minimum Voltage to Light Alarm LED: 5 V Alarm Reset Voltage: Alarm Reset Time: One second Alarm Indicator: Integral indicator with 360º visibilityOperating & Storage Temperature: -40ºC to +70ºCOperation:Open-web casing that enables air to flow freely across a thermistor which measures the air temperature every two seconds A microprocessor stores the temperatures and compares them with pre-set values to determine whether a fixed upper limit - the alarm level - has been reachedDetectors the microprocessor uses algorithms to determine how fast the temperature is increasing
Specification | Value | |
---|---|---|
MFG NO | OMHD-04-DB-R | |
SKU | 6209106 | |
UPC | 619749321088 |
Rate-of-Rise Heat Detector with BaseThe Fireboy-Xintex Heat Detector uses a single thermistor to sense the air temperature around the detector. This heat detector was designed to detect how fast the temperature is increasing.Features:163°F Rate-of-Rise Heat DetectorHousing: White flame-retardant polycarbonateTerminals: Nickel-plated stainless steelIdeal in environments that are dirty or smokyUnaffected by wind or atmospheric pressureRemote test featureSpecifications:Detection Principle: Measurement of heat using a thermistorSampling Frequency: Once every four secondsSupply Voltage: 8.5 V dc to 33 V dcSupply Wiring: Two wire supply, polarity sensitivePower-up Time: Minimum: ‘detector active’ voltage: 6 VHolding Voltage: 5 V - 33 VMinimum Holding Current: 8 mA Minimum Voltage to Light Alarm LED: 5 V Alarm Reset Voltage: Alarm Reset Time: One second Alarm Indicator: Integral indicator with 360º visibilityOperating & Storage Temperature: -40ºC to +70ºCOperation:Open-web casing that enables air to flow freely across a thermistor which measures the air temperature every two seconds A microprocessor stores the temperatures and compares them with pre-set values to determine whether a fixed upper limit - the alarm level - has been reachedDetectors the microprocessor uses algorithms to determine how fast the temperature is increasing
0 | Total: $0.00 |